Place the machine on its front side.
Remove lead wire connector from the motor.
Loose mounting screws and remove V-belt.
Remove screws mounting the motor and remove the motor.
NOTE
After replace the motor, Adjust tension of the V-belt properly, then it shall be set for initial mode of the V-belt on Test Runnning without water.